DisplayCAL for Linux 3.8.9.3 freeware

Calibrate and characterize your display devices using one of the many supported hardware sensors, with support for multi-display setups and a variety of available settings like customizable whitepoint, luminance, black level, tone response curve as well as the option to create matrix and look-up-table ICC profiles, with optional gamut mapping. ...

Author Florian Hoch
Released 2019-12-15
Filesize 1.00 MB
Downloads 220
OS Linux
Installation
Keywords Argyll CMS calibration, Argyll CMS profile, display correction, calibrate, colorimeter, Argyll, correct
Users' rating
(10 rating)
DisplayCAL for LinuxOtherLinux
DisplayCAL for Linux - open tab Freeware Download Notice

DisplayCAL for Linux Free Download - we do not host any DisplayCAL for Linux torrent files or links of DisplayCAL for Linux on rapidshare.com, depositfiles.com, megaupload.com etc. All DisplayCAL for Linux download links are direct DisplayCAL for Linux download from publisher site or their selected mirrors.

DisplayCAL for Linux freeware - The Latest User Reviews
DisplayCAL for Linux freeware - The Latest Versions History
3.8.9.3 Dec 15, 2019 New Release Cosmetic UI Improve PCS to device gamut outline plot.
3.8.9.2 Dec 13, 2019 New Release When previous instance was force quit, override leftover lockfile.
When using a custom profiling testchart with very few or no dark RGB gray patches, try to better maintain slope of existing points during shaper curve generation.
3.8.9.1 Dec 8, 2019 New Release Enhancement: Show the instrument serial number (if available) when prompting to physically interact with the instrument.
Enhancement: Check SpyderX dark offset calibration and abort if it is too high (user error).
Enhancement: Adjust perceptual device to PCS table black point to match perceptual PCS to device table.
Enhancement: Warn during automatic output levels detection if the display device input range or graphics driver output range look to be misconfigured.
Enhancement: Profile loader (Windows): Use an alternate method to enforce single instance if local IPC is blocked.
Tone response curve plot now uses the illuminant-relative profile whitepoint instead of D50 for input values if using absolute colorimetric intent.
Rename “LG OLED” (.dcl) 3D LUT format to “DeviceControl” and unlock available resolutions.

Most popular Other freeware downloads

Scanlationshop

0.8.1.41192 B freeware download

... And for all these, you would have to tab between the applications: change image to the next one in your image viewer, then tab to your text script and write, and then ...

Songview

4.519 freeware download

... song slide? Just right click on the slide, open the slide editor, make the changes and close ... work with songs, select the Numbers or Titles tab. The numbers tab is useful if you want ...

SNFaceCrop

1.4.4354.42696 freeware download

... or copied into the Windows clipboard. SNFaceCrop uses OpenCV library. SNFaceCrop is very easy to use. ... original image are now located in the same tab/window so you can view the original image and ...

dispcalGUI Portable

3.8.9.3 freeware download

... calibration and profiling tools of Argyll CMS, an open source color management system by Graeme Gill. ... copy & paste from CGATS, CSV files (only tab-delimited) and spreadsheet applications. ...

dispcalGUI for Mac OS X

3.8.9.3 freeware download

... calibration and profiling tools of Argyll CMS, an open source color management system by Graeme Gill. ... copy & paste from CGATS, CSV files (only tab-delimited) and spreadsheet applications. ...

DisplayCAL for Linux

3.8.9.3 freeware download

... At its core it relies on ArgyllCMS, an open source color management system, to take measurements, create ... copy & paste from CGATS, CSV files (only tab-delimited) and spreadsheet applications, for profile verification and evaluation. ...