TARQUIN for Linux 4.3.6 freeware
... to aid the characterisation of pathologies, in particular brain tumours, both non-invasively with in-vivo 1H MRS and ex-vivo with 1H HR-MAS. ...
Author | Greg Reynolds and Martin Wilson |
Released | 2015-04-22 |
Filesize | 29.60 MB |
Downloads | 630 |
OS | Linux |
Installation | Instal And Uninstall |
Keywords | fit MRS data, analyze MRS data, MRS data analyzer, simulate, fit, analyze |
Users' rating (7 rating) |
TARQUIN for Linux Free Download - we do not host any TARQUIN for Linux torrent files or links of TARQUIN for Linux on rapidshare.com, depositfiles.com, megaupload.com etc. All TARQUIN for Linux download links are direct TARQUIN for Linux download from publisher site or their selected mirrors.
4.3.6 | Apr 22, 2015 | New Release | Tentative support for DICOM, SPAR/SDAT, IMA and RDA formats for 3D MRSI. Dynamics scans can now be filtered prior to averaging by specifying a csv file (--av_list). Useful for fMRS studies. Bug fix for GUI where program crashes following fitting. Bug fix for GE p-files Rdb reader rev : 14.3 and 16.0 where the offset to data was incorrect by one frame. This caused a crash at the reconstruction stage. |
4.3.5 | Jan 9, 2015 | New Release | FIDs can be truncated prior to pre-processing to remove unnecessary noisy data points - saving memory and disk space for large MRSI datasets (--trunc_pts). Improvement to reduce memory use when exporting large csv fit data files. Bug fix where Cit was included in the default basis set for the GUI. Bug fix for GE p-files where the offset to data was incorrect for rdb_header_rev 24,20. - Thanks to Felix Raschke for pointing this out. |
4.3.4 | Aug 12, 2014 | New Release | FIDs can be truncated prior to pre-processing to remove unnecessary noisy data points - saving memory and disk space for large MRSI datasets (--trunc_pts). Improvement to reduce memory use when exporting large csv fit data files. Bug fix where Cit was included in the default basis set for the GUI. Bug fix for GE p-files where the offset to data was incorrect for rdb_header_rev 24,20. - Thanks to Felix Raschke for pointing this out. Modest SNR improvement for multi-channel GE SVS coil combination (now weighted by water amplitude where available). Thanks to Felix Raschke and Jamie Near for letting me know that this is a better approach than un-weighted combination. Improvements to default MRI window level and window width parameters. Improvements to SPAR/SDAT SVS and 2D MRSI display on MRI. The number of components used in the HSVD water removal can now be specified (--hsvd_comps). |